Location:
Solar Array:
PV Modules:
Mounting:
Inverter Brand:
Protection:
Main Power Connection:
Gingin
3MW DC / 2.5MW AC
Longi 435W
NEXTracker Single Axis Tracking
SMA
Jarrah Customized Solution
1.9km Overhead to Connection Point
This project was delivered under a EPCM commercial arrangement for Climate Capital in 2020, on time, under budget, on schedule and with an excellent safety record under Image Resources delegated authority.
Avora Energy also have the maintenance contract for this installation, visiting site every 3 months to conduct planned maintenance and routine inspections.
Location:
Solar Array:
Battery:
PV Modules:
Mounting:
Inverter Brand:
Battery Brand:
Control:
Main Power Connection:
Mandurah
1.2MW DC / 1MW AC
2.5MWh / 1MW
Longi 440W Bi-Facial
NEXTracker Single Axis Tracking
FIMER
SAFT
Jarrah Customized Solution
Underground to Substation
This project was delivered under a EPCM commercial arrangement for Peel Renewable Energy in 2020, on time, under budget, on schedule and with an excellent safety record under TasGas and Development WA delegated authority.
Avora Energy also have the maintenance contract for this installation, visiting site every 3 months to conduct planned maintenance and routine inspections.
Location:
Solar Array:
Battery:
Diesel Backup
PV Modules:
Mounting:
Inverter Brand:
Battery Brand:
Main Power Connection:
Yallingup
230kW DC / 200KW AC
615kWh / 250KW
2*176KVA Blue Diamond Gensets
Risen 400W
Clenergy Fixed Tilt Mount
AlphaESS
AlphaESS
Underground to MSB
This project was delivered under a EPCM commercial arrangement for a private client in 2020, on time, under budget, on schedule and with an excellent safety record under Avora Energy WHS Systems.
Avora Energy also have the maintenance contract for this installation, visiting site every 3 months to conduct planned maintenance and routine inspections.
Location:
Solar Array:
Battery:
Diesel Backup
PV Modules:
Mounting:
Inverter Brand:
Battery Brand:
Main Power Connection:
York
40KW DC / 50kW AC
97kWh / 50kW
2*50kVA Blue Diamond Gensets
Longi 370W
Clenergy Roof Mounting
AlphaESS
AlphaESS
Underground to Household
This project was delivered under a EPCM commercial arrangement for a private client in 2020, on time, under budget, on schedule and with an excellent safety record under Avora Energy WHS Systems.
Avora Energy also have the maintenance contract for this installation, visiting site every 3 months to conduct planned maintenance and routine inspections.